Sialic Acid-Engineered IL4-10 Fusion Protein is Bioactive and Rapidly Cleared from the Circulation.

Abstract

CONCLUSIONS

Differential sialylation of IL4-10 fusion protein does not affect the in vitro and in vivo activity, but clearly results in a difference in systemic exposure. The rapid systemic clearance of low sialylated IL4-10 FP could be a favorable characteristic to minimize systemic exposure after administration in a local compartment.

PURPOSE

Modulating sialylation of therapeutic glycoproteins may be used to influence their clearance and systemic exposure. We studied the effect of low and high sialylated IL4-10 fusion protein (IL4-10 FP) on in vitro and in vivo bioactivity and evaluated the effect of differential sialylation on pharmacokinetic parameters.

METHODS

CHO cell lines producing low (IL4-10 FP lowSA) and high sialylated (IL4-10 FP highSA) fusion protein were generated. Bioactivity of the proteins was evaluated in an LPS-stimulated whole blood assay. Pharmacokinetics were studied in rats, analyzing plasma levels of IL4-10 FP upon intravenous injection. In vivo activity was assessed in an inflammatory pain mice model upon intrathecal injection.

RESULTS

IL4-10 FP lowSA and IL4-10 FP highSA had similar potency in vitro. The pharmacokinetics study showed a 4-fold higher initial systemic clearance of IL4-10 FP lowSA, whereas the calculated half-life of both IL4-10 FP lowSA and IL4-10 FP highSA was 20.7 min. Finally, both IL4-10 FP glycoforms inhibited persistent inflammatory pain in mice to the same extent.

More about this publication

Pharmaceutical research
  • Volume 37
  • Issue nr. 2
  • Pages 17
  • Publication date 26-12-2019

This site uses cookies

This website uses cookies to ensure you get the best experience on our website.