Radiotherapy treatment plans and computed tomography scans were collected for 350 treatments in a variety of tumor sites. Dose distributions were computed using a MC dose engine for
DL dose evaluation was on average 82 times faster than MC computation at a 1 % accuracy setting. In voxels receiving at least 10 % of the maximum dose the overall global gamma pass rate using a 2 % and 2 mm criterion was 99.6 %, while mean local gamma values were accurate within 2 %. In the high dose region over 50 % of maximum the mean local gamma approached a 1 % accuracy.
A DL based dose engine was implemented, able to accurately reproduce MC computed dynamic arc radiotherapy dose distributions at high speed.
Despite hardware acceleration, state-of-the-art Monte Carlo (MC) dose engines require considerable computation time to reduce stochastic noise. We developed a deep learning (DL) based dose engine reaching high accuracy at strongly reduced computation times.